V6N1_Measurements To Glass
A manufacturer of medical equipment needed to automate a manual process of aligning their glass encoder disc to a drive motor hub.
Download PDFCONTOURED GLASS INSPECTION
Application Note V9N1 January 2009
Can be inspected for conformance to a master shape ± 50 µm
If the sensors have been calibrated To glass of the same type and thickness.
Fiber Optic Probe
Emitted light reflected from the target is returned to the probes for single-sided measurements.
With glass targets, light is reflected from the front and back surfaces
The strength of the back side reflection is dependent upon glass thickness and amount of tint
Painted Glass has no back side reflection
Fiber Optic Probes are Calibrated By FixturingThem Perpendicular To The Glass Sample Which Is Mounted On a Linear Motion Stage
Calibration Samples
Are Stored In Sensor Memory
One Sensor
For more info on 10 channel racks, see the Product Data Sheet
http://www.philtec.com/datasheet10dms.pdf
An Array Of Sensors Is Mounted In A Master Frame
Readings From 50 Sensors Can Be Recorded in
Less Than 1 Second
Philtec Provides Software for
Controlling 1 – 10 Sensors
LabVIEW and VB6 Drivers are available for programmers.
Fiber Optic Sensors
Use RC Type (Reflectance Compensated) Sensors Select Model Based Upon Gaging Distances (RC100, RC171) Customize Sensor Tip As Desired (Length & Diameter) Specify Fiber Optic Cable Length Use Interlocking SS Cable Sheathing Sensor Electronics Include Ambient Light Rejection