Reflectance Dependent Models – Analog

Philtec Model D170

Technical datasheet for the Philtec Model D170 reflectance-dependent analog fiberoptic displacement sensor. Ø 4.32 mm spot size, 30 mm total operating range, and 0.3 mV/µm far side sensitivity.

Philtec analog amplifier Model D170 fiberoptic cable and sensor tip
Model D170 amplifier, 914 mm cable, and 4.75 mm probe tip

Technical datasheet for the Philtec Model D170 reflectance-dependent analog fiberoptic displacement sensor. Ø 4.32 mm spot size, 30 mm total operating range, and 0.3 mV/µm far side sensitivity.

Spot size4.32 mm0.170 in (targets > Ø 4.4 mm)
Total range30 mm29.1 mm (1.15 in) far side
Far side0.3 mV/µm300 mV/mm (8.2 mV/mil) nominal
Linear range6 mm0.240 in far side nominal
BandwidthDC–20 kHzDC–200 kHz / 2 MHz or DC–100 Hz opt.

Overview

The Philtec Model D170 is a reflectance-dependent analog fiberoptic sensor for the measurement of distance, displacement, and vibration of targets larger than Ø 4.4 mm (Ø 4.32 mm / 0.170 inch target spot size). Standard single-channel units include the amplifier and sensor tip with a 914 mm (3 foot) fiberoptic cable, require +12 VDC input power (+12 to +24 VDC operating range), and provide a 0 to +5 volt analog output with DC–20 kHz bandwidth.

Output voltage is proportional to both the distance between the sensor tip and target and the reflectivity of the target surface. The Far Side output function starts at the maximum output voltage referred to as the OPTICAL PEAK (set to 5.000 V at factory calibration), and incoming light signals are bandpass filtered at 850 ± 22 nm for ambient light rejection. D models are commonly used where target reflectivity stays constant, such as reciprocating or vibratory motion parallel to the axis of the sensor.

5.0 V 3.3 V 1.7 V 0.0 V OPTICAL PEAK (5.000 V) NEAR SIDE FAR SIDE Increasing Gap >>>
Figure 1. Near side, optical peak, and far side
  • Near side: steep slope rising to the optical peak as tip-to-target gap increases from contact.
  • Optical peak: maximum output voltage set to 5.000 V at factory calibration; gain control calibrates other target surfaces to 5 V.
  • Far side: primary calibrated region starting at the optical peak and extending across 29.1 mm (1.15 in) / 30 mm total range.

Specifications

Standard specifications — D170 Far Side (Analog Output 0–5 Volts)

Parameter Metric Imperial
Total range 29.1 mm (30 mm feature) 1.15 in
Linear range* 6 mm 0.240 in
Nominal standoff* 3.8 mm 0.150 in
Nominal sensitivity* 300 mV/mm (0.3 mV/µm feature) 8.2 mV/mil
Resolution**, DC–200 kHz 14 µm 550 µin
Resolution**, DC–20 kHz 7 µm 275 µin
Resolution**, DC–100 Hz 1 µm 40 µin

Tip and cable dimensions

Feature Metric (mm) Imperial (inch)
Tip outer diameter (Ø C) 4.75 0.187
Fiberoptic diameter 4.32 0.170
Tip length (C) 76.2 3
Collar length (B) 15.9 0.625
Collar diameter (Ø B) 7.92 0.312
Cable length (A) 914 36
Cable diameter (Ø A) 6.86 0.27
Cable min. bend radius 25.4 1

Amplifier enclosure dimensions

Dimension Metric (mm) Imperial (inch)
Body length 127.7 5.028
Flange overall length 139.2 5.48
Body width 82.4 3.24
Mounting slot spacing 54.6 2.15
Height 47.6 1.87
Flange thickness 1.6 0.063
Mounting slots (4 slots) 4 × 9.5 0.157 × 0.375

Electronics

Light sourceLED, 850 nm (bandpass filtered at 850 ± 22 nm)
Input voltage+12 to +24 VDC
Input current125 mA max
BandwidthDC–20 kHz (3 dB down) standard; DC–200 kHz or higher (up to 2 MHz) and DC–100 Hz optional
Isothermal drift0.5%
Operating temperature0 to 70 °C
Weight0.7 kg (1.5 lb)

Fiberoptics

Light beam spread25°
Tip material300 Series SS
Tip epoxy outgas0.3% @ 200 °C; 2.4% @ 300 °C
Tip operating pressure15 bar
Tip operating temperature−55 to 200 °C continuous; to 300 °C intermittent (1–2 hours)
Cable operating temperature10 to 107 °C
Cable jacketPVC over Steel Monocoil

Nominal standoff is the gap (distance) that places the sensor at the middle of the linear operating range. *Standard specifications provide nominal values only; actual production values may vary by as much as ±15%.

**Resolution figures represent best-case performance where: the target is flat, smooth, and highly reflective; the sensor is perpendicular to the target; the sensor is gapped to its range of highest sensitivity; and fiberoptic cable lengths are standard with an unconnectorized cable.

Response curves

PHILTEC Model D170 — Typical Response (Far Side) 5.0 4.0 3.0 2.0 1.0 0.0 0 5 10 15 20 25 30 Gap, mm SENSITIVITY = −0.30 mV/µm
Figure 2. Model D170 typical response — Far Side (−0.30 mV/µm)
  • Linear range, Far Side, ±1%: 1.64 – 9.25 mm (6 mm nominal linear range).
  • Starts at the 5.000 V optical peak and decreases across the far side out to ~29.1–30 mm.
PHILTEC Typical Model — Far Side (Front Surface Mirror) 5.0 4.0 3.0 2.0 1.0 0.0 0 0.2 0.4 0.6 0.8 1.0 Gap, mm SENSITIVITY = −6 mV/µm
Figure 3. Typical Far Side calibration example to front surface mirror
  • Linear range, Far Side, ±1%: 0.31 – 0.61 mm; Far Side Y-intercept: 6.709 V.
  • Noise ripple @ 3.5 VDC (DC–20 kHz): 6 mV pk-pk.
Typical Frequency Response — 2 Pole Butterworth Filter 0 -3 -6 -9 100 1000 10000 100000 Frequency, Hz
Figure 4. Typical frequency response — 2-pole Butterworth filter
  • Standard D sensor features a 20 kHz 2-pole Butterworth rolloff (−3 dB at 20 kHz).
  • Output remains flat out to approximately 6 kHz.

Converting analog output to distance

Each sensor includes a Far Side calibration chart detailing model/serial number, calibration date, linear range, slope sensitivity, y-intercept, and AC noise ripple (XY data points available upon request).

  1. Linear range: Distance (µm) = Δ milliVolts ÷ Sensitivity.
  2. Non-linear range: create a lookup table from the XY calibration data points.
  3. Curve fit: use a polynomial curve fit to map the sensor output function.

1,000.0 µm (1.000 mm)

Calibration & Conversions

End user calibration

Changing target reflectance shifts the voltage output higher or lower. Factory calibrations set the Optical Peak to 5.000 V, and a gain control calibrates the sensor to other target surfaces:

  1. Adjust the tip-to-target gap until the peak output voltage is attained.
  2. Use the gain control to set the peak voltage to full scale (5.000 V).
  3. Apply the factory gap calibration chart for precision linear motion measurements on the target material.

Unit conversions & contact

1 µm39.37 µinch
1 mm39.37 mils
1 mil0.001 inch = 25.4 µm = 0.0254 mm
ManufacturerPHILTEC, Inc., Annapolis, MD USA
Phone / Fax / Email410-757-4404 · Fax 410-757-8138 · sensors@philtec.com

Frequently asked questions

What target size and surface motion suit the Model D170?

The D170 has a Ø 4.32 mm (0.170 in) spot size and is intended for targets larger than Ø 4.4 mm. Because output is proportional to both gap and surface reflectivity, D models are best suited where target reflectivity remains constant, such as reciprocating or vibratory motion parallel to the sensor axis.

How is ambient light rejected?

Incoming light signals are bandpass filtered at a wavelength of 850 ± 22 nm to reject unwanted ambient light interference.

What bandwidth options are available?

DC–20 kHz (3 dB down, flat out to ~6 kHz) is standard. Optional bandwidths include DC–200 kHz or higher (up to 2 MHz) for faster dynamics, and DC–100 Hz for best resolution.