Reflectance Dependent Models – Analog

Philtec Model D240

Technical datasheet for the Philtec Model D240 reflectance-dependent analog fiberoptic displacement sensor. Ø 6.1 mm target spot size, 76 mm total operating range, and 0.2 V/mm far side sensitivity.

Philtec analog amplifier with the D240 probe Model D240 fiberoptic cable and sensor tip
Model D240 amplifier, 914 mm cable, and 7.92 mm probe tip

Technical datasheet for the Philtec Model D240 reflectance-dependent analog fiberoptic displacement sensor. Ø 6.1 mm target spot size, 76 mm total operating range, and 0.2 V/mm far side sensitivity.

Spot size6.1 mm0.240 in (targets > Ø 6.1 mm)
Total range76 mm62 mm (2.4 in) far side spec
Far side0.2 V/mm−0.186 V/mm curve (5 mV/mil)
Linear range10 mm0.400 in far side nominal
BandwidthDC–20 kHzDC–200 kHz / 2 MHz or DC–100 Hz opt.

Overview

The Philtec Model D240 is a reflectance-dependent analog fiberoptic sensor for the measurement of distance, displacement, and vibration of targets larger than Ø 6.1 mm (Ø 6.1 mm / 0.240 inch target spot size, 76 mm total operating range). Standard single-channel units include the amplifier and sensor tip with a 914 mm (3 foot) fiberoptic cable, require +12 VDC input power (+12 to +24 VDC operating range), and provide a 0 to +5 volt analog output with DC–20 kHz bandwidth.

Output voltage is proportional to both the distance between the sensor tip and target and the reflectivity of the target surface. The output function includes a maximum output voltage region referred to as the OPTICAL PEAK; usable operation includes linear ranges on both sides of the peak as well as at the peak itself. Near Side operation provides high sensitivity with limited operating range, while Far Side operation provides moderate sensitivity with greater operating range. Incoming light signals are bandpass filtered at 850 ± 22 nm for ambient light rejection.

5.0 V 3.3 V 1.7 V 0.0 V OPTICAL PEAK (5.000 V) NEAR SIDE FAR SIDE Increasing Gap >>>
Figure 1. Near side, optical peak, and far side
  • Near side: high sensitivity with limited operating range as gap rises toward the optical peak.
  • Optical peak: maximum output voltage set to 5.000 V at factory calibration; gain control calibrates other target surfaces to 5 V.
  • Far side: moderate sensitivity with greater operating range across 62 mm (2.4 in) / 76 mm total range.

Specifications

Standard specifications — D240 Far Side (Analog Output 0–5 Volts)

Parameter Metric Imperial
Total range 62 mm (76 mm total operating range) 2.4 inch
Linear range* 10 mm 0.400 inch
Nominal standoff* 22 mm 0.9 inch
Nominal sensitivity* 0.19 V/mm (0.2 V/mm feature; −0.186 V/mm curve) 5 mV/mil
Resolution**, DC–200 kHz 25 µm 1000 µin
Resolution**, DC–20 kHz 12 µm 500 µin
Resolution**, DC–100 Hz 4 µm 170 µin

Tip and cable dimensions

Feature Metric (mm) Imperial (inch)
Tip outer diameter (Ø C) 7.92 0.312
Fiberoptic diameter 6.10 0.240
Tip length (C) 76.2 3.0
Collar length (B) 19.1 0.75
Collar diameter (Ø B) 9.53 0.375
Cable length (A) 914 36
Cable diameter (Ø A) 8.6 0.340
Cable min. bend radius 40 1.6

Amplifier enclosure dimensions

Dimension Metric (mm) Imperial (inch)
Body length 127.7 5.028
Flange overall length 139.2 5.48
Body width 82.4 3.24
Mounting slot spacing 54.6 2.15
Height 47.6 1.87
Flange thickness 1.6 0.063
Mounting slots (4 slots) 4 × 9.5 0.157 × 0.375

Electronics

Light sourceLED, 850 nm (bandpass filtered at 850 ± 22 nm)
Input voltage+12 to +24 VDC
Input current125 mA max
BandwidthDC–20 kHz (3 dB down) standard; DC–200 kHz or higher (up to 2 MHz) and DC–100 Hz optional
Isothermal drift0.5%
Operating temperature0 to 70 °C
Weight0.8 kg (1.8 lb)

Fiberoptics

Light beam spread25°
Tip material300 Series SS
Tip epoxy outgas0.3% @ 200 °C; 2.4% @ 300 °C
Tip operating pressure15 bar
Tip operating temperature−55 to 200 °C continuous; to 300 °C intermittent (1–2 hours)
Cable operating temperature10 to 107 °C
Cable jacketPVC over Steel Monocoil

Nominal standoff is the gap (distance) that places the sensor at the middle of the linear operating range. *Standard specifications provide nominal values only; actual production values may vary by as much as ±15%.

**Resolution figures represent best-case performance where: the target is flat, smooth, and highly reflective; the sensor is perpendicular to the target; the sensor is gapped to its range of highest sensitivity; and fiberoptic cable lengths are standard with an unconnectorized cable.

Response curves

PHILTEC Model D240 — Typical Response (Far Side) 5 4 3 2 1 0 0 10 20 30 40 50 60 70 Gap, mm SENSITIVITY = −0.186 Volt/mm
Figure 2. Model D240 typical response — Far Side (−0.186 V/mm)
  • Linear range, Far Side, ±1%: 17 – 27 mm (10 mm nominal linear range).
  • Nominal sensitivity: 0.19 V/mm (5 mV/mil); 0.2 V/mm feature sensitivity.
PHILTEC Typical Model — Far Side (Front Surface Mirror) 5.0 4.0 3.0 2.0 1.0 0.0 0 0.2 0.4 0.6 0.8 1.0 Gap, mm SENSITIVITY = −6 mV/µm
Figure 3. Typical Far Side calibration example to front surface mirror
  • Linear range, Far Side, ±1%: 0.31 – 0.61 mm; Far Side Y-intercept: 6.709 V.
  • Noise ripple @ 3.5 VDC (DC–20 kHz): 6 mV pk-pk.
Typical Frequency Response — 2 Pole Butterworth Filter 0 -3 -6 -9 100 1000 10000 100000 Frequency, Hz
Figure 4. Typical frequency response — 2-pole Butterworth filter
  • Standard D sensor features a 20 kHz 2-pole Butterworth rolloff (−3 dB at 20 kHz).
  • Output remains flat out to approximately 6 kHz.

Converting analog output to distance

Factory calibration charts are provided for Near and Far Side regions, listing sensor model & serial number, calibration date, linear sensing range, slope sensitivity, y-intercept, and AC noise ripple (XY data points available upon request).

  1. Linear range: Distance (µm) = Δ milliVolts ÷ Sensitivity.
  2. Non-linear range: create a lookup table from the XY calibration data points.
  3. Curve fit: use a polynomial curve fit to map the sensor output function.

1,000.0 µm (1.000 mm)

Calibration & Conversions

End user calibration

Changing target reflectance shifts the voltage output higher or lower. Factory calibrations set the Optical Peak to 5.000 V, and a gain control calibrates the sensor to other target surfaces:

  1. Adjust the tip-to-target gap until the peak output voltage is attained.
  2. Use the gain control to set the peak voltage to full scale (5.000 V).
  3. Apply the factory gap calibration chart for precision linear motion measurements on the target material.

Unit conversions & contact

1 µm39.37 µinch
1 mm39.37 mils
1 mil0.001 inch = 25.4 µm = 0.0254 mm
ManufacturerPHILTEC, Inc., Annapolis, MD USA
Phone / Fax / Email410-757-4404 · Fax 410-757-8138 · sensors@philtec.com

Frequently asked questions

What target size and surface motion suit the Model D240?

The D240 has a Ø 6.1 mm (0.240 in) target spot size and is intended for targets larger than Ø 6.1 mm across a 76 mm total operating range. Because output is proportional to both gap and surface reflectivity, D models are best suited where target reflectivity remains constant, such as reciprocating or vibratory motion parallel to the sensor axis.

How is ambient light rejected?

Incoming light signals are bandpass filtered at a wavelength of 850 ± 22 nm to reject unwanted ambient light interference.

What bandwidth options are available?

DC–20 kHz (3 dB down, flat out to ~6 kHz) is standard. Optional bandwidths include DC–200 kHz or higher (up to 2 MHz) for faster dynamics, and DC–100 Hz for best resolution.