+1 410-757-4404 sensors@philtec.com

50-MRI

Philtec’s ϐiber optic sensors are playing a vital role in a prototype which is very important for assessing the design. Displacements of many items inside the cryogenic system are being measured successfully to sub-micron level resolution.

Download PDF

GAP SENSORS FOR MRI APPLICATIONS

The 11.7T Whole Body MRI – The Iseult project under development at CEA-Saclay, in collaboration with Siemens Healthcare and Alstom Magnets and Superconductors, is scheduled for commissioning in 2012.

Philtec’s fiber optic sensors are playing a vital role in a prototype which is very important for assessing the design. Displacements of many items inside the cryogenic system are being measured successfully to sub-micron level resolution.

CEA-Saclay and Siemens Healthcare, in collaborating their research activities for the 11.7T MRI, have purchased Philtec sensor systems for the following applications:

SIEMENS: Measure ±2mm range displacement of the Magnet Structural Elements Liquid Helium @ 1.8K High Magnetic Field 11.7 T Pressure 15 mbar 21 x Philtec model RC100 with 8.3 m length FO cables

Philtec is a world-wide leading supplier of fiber optic

displacement sensor systems for operation in very

extreme environments, including:

High Magnetic Field High Voltage High Pressure High/Low Temperatures Immersion In Cryo Fluids

CEA-SACLAY Prototype R0: To apply a mechanical Von Mises stress equivalent to that of Iseult.

Measure ±2 mm range displacement of superconductor Liquid helium @ 1.8K High Magnetic Field 11.7T Pressure 15 mbar 3 x Philtec model RC170 with 6 m length FO cables

CEA-SACLAY Prototype Q0: Model the mechanical behaviour of the double pancake assembly stacks preloaded inside the helium vessel. Measure ±2 mm range displacement of superconductor Gaseous helium @ 6 K to 300 K No Magnetic Field Ambient Pressure 12 x Philtec model RC100 with 6 m length FO cables

Questions and answers

What does 50-MRI cover?

Philtecu2019s fiber optic sensors are playing a vital role in a prototype which is very important for assessing the design.

Which Philtec sensor models are mentioned?

This document mentions RC100, RC170.