+1 410-757-4404 sensors@philtec.com

78_Turbine Speed Probe

A Ø 1.5 mm test probe was made with the fi bers polished to a 30° angle. The emittted light beam was observed to spread over a 50° angle

Download PDF

THE PROBLEM A customer wants to measure turbine speed by detecting the passage of 1 mm thick turbine blades. However, access to the blades can only be made at a 50° angle.

TEST METHOD A Ø 1.5 mm test probe was made with the fibers polished to a 30° angle. The emittted light beam was observed to spread over a 50° angle mm Travel

Volts

Volts

A 1 mm turbine blade was placed on a linear stage and mounted at 30° and 50° angles to the test probe. The probe output was recorded as the blade was moved across the probe’s light beam.

RESULTS 30° Angle 4.5 = peak volts over the blade 0.5 = minimum voltage off blade SNR = 9

Angle Polished Probes for Turbine Speed Detection

RESULTS 50° Angle 3.5 = peak volts over the blade 0.8 = minimum voltage off blade SNR = 4.4

CONCLUSION Angle polished probes can detect turbine blade passage up to a 50° access angle.

Questions and answers

What does 78_Turbine Speed Probe cover?

A u00d8 1.5 mm test probe was made with the fibers polished to a 30u00b0 angle. The emittted light beam was observed to spread over a 50u00b0 angle