+1 410-757-4404 sensors@philtec.com

28_Fiberoptics For High Magnetic Fields

By jacketing the fiberoptic cable in non-metallic materials and constructing the sensor tip from non-metallic or non-magnetic materials, Philtec sensors can be configured to perform measurements in very high magnetic fields. Successful applications in environments of several Tesla have been reported.

Download PDF

Jan 2018 Fiberoptics For High Magnetic Fields

The Problem Fiberoptic probes and cables may be exposed to high magnetic fields.

The Solution By jacketing the fiberoptic cable in non-metallic materials, and by constructing the sensor tip from non-metallic or non-magnetic materials, Philtec sensors can be configured to perform measurements in very high magnetic fields. Successful applications to several Tesla have been reported.

Option Cable Jackets Max Temp. Features C2 Silicone Coated Fiberglass 200 C Maximum flexibility, no crush strength C3 Silicone over PTFE Wrap 200 C Light crush resistance, short lengths <2 m max. C4 Corrugated Plastic 85 C Semi-crush proof, MRI Compatible C6 PVC over Nylon 105 C Light crush resistance, long lengths OK C7 PTFE 260 C Zero outgassing, poor flexibility C8 PVC Only 105 C Good flexibility, no crush strength, long lengths OK C11 Polyolefin Shrink Tubing 135 C Poor flexibility, Good Vapor Barrier C13 Furcation tubing 85 C PVC/Kevlar/PTFE High Tensile Strength

Option Tips Max Temp. Features T3 Peek Plastic 250 C Non-metallic T3 Torlon 260 C Non-metallic T11 Aluminum 260 C Non-magnetic T11 Brass 800 C Non-magnetic

PVC Jacket / Peek Tubing

EXAMPLES

Silicone-PTFE Jacket / Torlon Tip

PTFE Jacket / Brass Tip

Peek Tip Threaded

Questions and answers

What does 28_Fiberoptics For High Magnetic Fields cover?

Jan 2018 Fiberoptics For High Magnetic Fields The Problem Fiberoptic probes and cables may be exposed to high magnetic fields.