78_Turbine Speed Probe
A Ø 1.5 mm test probe was made with the fi bers polished to a 30° angle. The emittted light beam was observed to spread over a 50° angle
Download PDFTHE PROBLEM A customer wants to measure turbine speed by detecting the passage of 1 mm thick turbine blades. However, access to the blades can only be made at a 50° angle.
TEST METHOD A Ø 1.5 mm test probe was made with the fibers polished to a 30° angle. The emittted light beam was observed to spread over a 50° angle mm Travel
Volts
Volts
A 1 mm turbine blade was placed on a linear stage and mounted at 30° and 50° angles to the test probe. The probe output was recorded as the blade was moved across the probe’s light beam.
RESULTS 30° Angle 4.5 = peak volts over the blade 0.5 = minimum voltage off blade SNR = 9
Angle Polished Probes for Turbine Speed Detection
RESULTS 50° Angle 3.5 = peak volts over the blade 0.8 = minimum voltage off blade SNR = 4.4
CONCLUSION Angle polished probes can detect turbine blade passage up to a 50° access angle.