+1 410-757-4404 sensors@philtec.com

V6N1_Measurements To Glass

A manufacturer of medical equipment needed to automate a manual process of aligning their glass encoder disc to a drive motor hub.

Download PDF

CONTOURED GLASS INSPECTION

Application Note V9N1 January 2009

Can be inspected for conformance to a master shape ± 50 µm

If the sensors have been calibrated To glass of the same type and thickness.

Fiber Optic Probe

Emitted light reflected from the target is returned to the probes for single-sided measurements.

With glass targets, light is reflected from the front and back surfaces

The strength of the back side reflection is dependent upon glass thickness and amount of tint

Painted Glass has no back side reflection

Fiber Optic Probes are Calibrated By FixturingThem Perpendicular To The Glass Sample Which Is Mounted On a Linear Motion Stage

Calibration Samples

Are Stored In Sensor Memory

One Sensor

For more info on 10 channel racks, see the Product Data Sheet

http://www.philtec.com/datasheet10dms.pdf

An Array Of Sensors Is Mounted In A Master Frame

Readings From 50 Sensors Can Be Recorded in

Less Than 1 Second

Philtec Provides Software for

Controlling 1 – 10 Sensors

LabVIEW and VB6 Drivers are available for programmers.

Fiber Optic Sensors

Use RC Type (Reflectance Compensated) Sensors Select Model Based Upon Gaging Distances (RC100, RC171) Customize Sensor Tip As Desired (Length & Diameter) Specify Fiber Optic Cable Length Use Interlocking SS Cable Sheathing Sensor Electronics Include Ambient Light Rejection

Our Application Engineers are Ready To Help You

E-mail to Sensors@Philtec.com

Questions and answers

What does V6N1_Measurements To Glass cover?

A manufacturer of medical equipment needed to automate a manual process of aligning their glass encoder disc to a drive motor hub.

Which Philtec sensor models are mentioned?

This document mentions RC100, RC171.