+1 410-757-4404 sensors@philtec.com

60_Long Cables

Reference table of maximum continuous cable lengths by sensor model. Covers one-piece, in-line connector, vacuum passthru, extension cable, and bulkhead connector system configurations for extending fiber optic cable reach.

Download PDF

Long Fiber Optic Cables

The standard fiber optic cable length is 3 feet (914 mm). Maximum cable lengths are limited by the type of fiber used with specific sensor models as shown in this table.

Maximum Continuous Cable Length Model Feet Meters Model Feet Meters D6 RC19 D12 RC20 D20 RC25 D21 RC32 D47 RC60 D63 RC62 D64 RC63 D100 RC90 D125 RC100 D169 RC125 D170 RC171 D171 RC190 D240 RC290

Amplifier

OPTIONS Cable lengths can be extended by adding in-line connectors. ~15 m of additional length can be added between the sensor amplifier and the in-line connector using efficient low-loss fibers. The maximum cable length – from the connector to the sensor tip – is limited by the values in the table above.

NOTES 1. Sensors with long cables will have higher noise levels than standard short length cables. 2. Please contact the factory if long cables are needed in combination with high bandwidth and/or dark targets.

Amplifier

In-Line Connector, Option B

Low Loss Fibers High Loss Fibers

Questions and answers

What does 60_Long Cables cover?

Maximum cable lengths and connector configurations for extended reach systems.

Which Philtec sensor models are mentioned?

This document mentions RC19, D12, RC20, D20, RC25, D21, RC32, D47, RC60, D63, RC62, D64.