+1 410-757-4404 sensors@philtec.com

29_Reflection Interference

Guidance on avoiding reflection interference when mounting fiber optic probe tips near sidewalls or adjacent probes. Covers numerical aperture, beam angle by fiber type, target spot size, and minimum spacing calculations for Philtec sensor models.

Download PDF

Refl ection Interference

How To Avoid Reflection Interference

The Problem To determine how close fiberoptic sensor tips can be mounted to sidewalls or to each other without interference.

The Solution Unlike laser sensors which collimate light to a point, Philtec’s fiberoptic probes spread light out like a fl ashlight. The angle the light beam spreads depends upon the specifi c model and it is provided on our Product Data Sheets for each model. Interference calculations can be made based upon the light beam spread and the operating gaps for any model sensor.

Numerical Aperture Numerical aperture (na) refers to the maximum angle at which light can enter, propogate thru and exit an optical fiber. Philtec uses 3 diff erent types of fibers to construct sensors. These fibers have the following properties:

FIBER na BEAM ANGLE Models D20, D63, RC19, RC25, RC31, RC59 D21, D47, D100, D125, D169, RC20, RC32, RC60, RC100 D170, D171, D240, RC171, RC225, RC290

Sensor Tip

Refl ection Interference

TARGET SPOT SIZE The target spot size is equal to the size of the fiber bundle. Any light rays that diverge away from the projected area of the fiber bundle are refl ected away from the sensor tip – unless the sensor is too close to some other object.

INTERFERENCE LIMITS

OPAQUE TARGETS D = 2*G*tan(naair/2)

na, degrees D 0.44*G 0.54*G 1.3*G

GLASS TARGETS D = 2*G*tan(naair/2) + 2*t*tan(naglass/2)

naair naglass D 0.44*G + 0.29t 0.54*G + 0.35t 1.3*G + 0.8t

EXAMPLE For a model RC171 sensor and opaque target, na = 25° and G = 12.7 mm. Therefore, D = 0.44 * 12.7; D = 5.6 mm For a model RC171 sensor and 4 mm glass target, D = 0.44 * 12.7 + 0.29 * 4; D = 6.8 mm

D = Interference Limit With Opaque Targets

G = Maximum Operating Gap

GLASS

D = Interference Limit With Glass Targets D

G = Maximum Operating Gap

Questions and answers

What does 29_Reflection Interference cover?

Avoiding optical interference when probes are mounted near walls or adjacent sensors.

Which Philtec sensor models are mentioned?

This document mentions D20, D63, RC19, RC25, RC31, RC59, D21, D47, D100, D125, D169, RC20.