84_Rocket Launch and Smallsat Apps
Overview of Philtec fiber optic displacement sensors for global space launch and small satellite applications: cryogenic rocket engine turbopumps, satellite propulsion in vacuum, aircraft engine testing, and custom multi-part sensor systems for extreme aerospace environments.
Download PDFAEROSPACE APPLICATIONS
Rocket Engine Turbopumps
CONDITIONS Cryogenic fluids LOX, CH4, Kerosene High Pressure
SENSOR REQUIREMENTS Custom Probe Casings 40-60 Ft long FO Cables Vibration Proof Connectors 75 KHz Sensor Bandwidth Multi-Part Systems
Aerospace Applications
Satellite Propulsion Systems
CONDITIONS Vacuum Linear translation Low Noise
Aerospace Applications
Sensor System with Vacuum Flange
FO Probe Inside Thrust Stand
Aircraft Engine Tests
CONDITIONS Bird Strikes Catastrophic Loss of an Engine
SENSOR REQUIREMENTS 30 mm Displacement of Engine Support Structure Side-Viewing Probes 12 m Fiberoptic Cables 20 KHz Sensor Bandwidth
Aerospace Applications
Philtec sensors were used to measure Thrust Reverser performance during static and flight tests of the A380.
90° Probe measured the distance between the inverter and engine.
SENSOR REQUIREMENTS ±15 mm Displacement -55°C to +150°C 90° Sensor Probes 300 Hz Frequency Response
Aerospace Applications
Flight Test Sensors
Weight: 2 lbs. amplifier; ¾ lb. each fiberoptic ass’y Displacement Range: 2 inch (50 mm) Vibration: 5 g rms, 5 Hz -2KHz, in any axis MS style connector for (+28 volt) input power and output signal Detachable Probes, Straight Tips and 90°Tips Tip Operating temp. -45C to 200C
Aerospace Applications
Small Flight Test Sensors
Sensor Features Electronics Weight : 6.5 ounces
Size : 25 x 50 x 75 mm (1” x 2” x 3”)
Input/Output via Micro-D Connector MIL-DTL-83513
Grounded Enclosure with Thru Hole Mounting
A customer required the smallest sensor for integration into a flying object.
Aerospace Applications
Small Flight Test Sensors
Brazed Window for P = 6 bars T<450°C
2 Connectors Enable Use Of Extension Cables
Small Lightweight Electronics Package
Aerospace Applications
Icing Research
Measure Wing Tip Vibrations
With Icing Conditions
Aerospace Applications
1,000,000 rpm Speed Counting
M.I.T. Columbia University Johns Hopkins Applied Physics Lab Onera, French Aerospace Lab
Micro-Turbine Development
Sensor Model D6
Fiber Optic Probe, Ø 150 µm
Aerospace Applications
Mars Rover Mission
NASA’s JPL Ultrasonic Driller
Developed by Cybersonics, Inc.
Philtec sensor model RC25-HQ was used to characterize the harmonic analysis and axial motion of the drill.
Aerospace Applications
Space Shuttle
NASA’s Marshall Space Flight Center used Philtec probes in a LOX pressurized cryogenic environment to monitor bearing deflections in the Space Shuttle Main Engine
Aerospace Applications
Space Shuttle
In the wake of the Challenger disaster, Thiokol engineers used Philtec sensors installed between the joints of rocket sections to determine how much separation occurred during firing.
Aerospace Applications
Probes For Cryogenic Turbo Pump
Aerospace Applications
To Measure Shaft Displacements
OPERATING ENVIRONMENT Hydrogen Gas (probe tip immersed) Operational Temp: 40°F Pressure: 1000 psig
OPERATING ENVIRONMENT Liquid Hydrogen (probe tip immersed) Operational Temp: -420°F Non-Op Temp: 0°F to 130°F Pressure: 2500psia (max)
These sensors were used to measure thermal distortions of critical components at low temperatures
Imager for the Hubble Replacement Telescope
Aerospace Applications
Philtec sensors were used to measure micron level mirror adjustments in high vacuum
Space Telescope Lens Focus
Multi-Channel Vacuum Passthru
Aerospace Applications
This 6-channel displacement measurement system with vacuum passthru hardware was used to measure displacements and calculate rotations of the satellite’s focal plane structure.
ESA’s Sentinel 3 Satellite
Aerospace Applications
Aerospace Applications High Speed Compressor Blade Vibration Tests
The compressor test rig uses a small axial blisk from a 2 stage LTS101 Turboshaft Engine.
Aerospace Applications High Speed Compressor Blade Vibration Tests
A High Speed Philtec D63 Probe was attached to the shroud and pointed radially inward at the blade tips.
The time of arrival (TOA) of each blade was recorded using an 80 MHz NI counter timer card.
The blade vibration can be detected directly from the deviation in expected arrival time curves for each blade.