+1 410-757-4404 sensors@philtec.com

71_Temperature Limits

Planning an installation in a high-temperature or extreme environment? Download Application Note 71 to verify the operational temperature ranges for our fiberoptic sensors. Use this reference to match the correct sensor tip, cable jacket, and electronics to your project's specific thermal profile.

Download PDF

SENSOR TIPS Standard sensor tips are constructed with glass fibers and stainless steel housings.

Cryogenic to 200°C continuous 300°C intermittent Standard, most models

250°C continuous to 300°C intermittent Option T8 High Temperature Epoxy

350°C continuous to 400°C intermittent Option T9 High Temperature Adhesive

900°F (482°C) Option T10 No Epoxy, Mechanically Bonded Fibers

800°C continuous Option T10F, Fused-End Quartz Fiber (Face Only)

FIBEROPTIC CABLE JACKETS Standard sensor cables use glass fibers with a protective jacket. The jacket materials limit the temperature range of the cables as shown below.

TEMPERATURE LIMITS OF CABLE JACKETS

Standard PVC/ Steel Monocoil. Good general purpose jacket. +10 to +107°C

C1 Interlocking Stainless Steel Hose. Provides high strength -150° to +400°C

C2 Silicone-Fiberglass/ Steel Monocoil. Flexible, radiation resistant -75 to +220°C

C3 Silicone Coated Fiberglass. Non-metallic, Flexible, radiation resistant -75 to +220°C

C5 PVC Over SS Interlock. Flexible. Does not stretch. Resists lateral pressure, twisting & pulling, withstands repeated bending,

C6 Convoluted PTFE. Semi-crush proof, good fl exibility, vapor barrier -270 to +260°C

C7 PTFE Tubing. MRI, EMF & vacuum compatible. Poor fl exibility, provides vapor barrier protection.

C8 PVC Only. Good fl exibility, no crush resistance, MRI & EMF compatible +10 to +105°C

C9 Annealed SS Tubing (semi-rigid) Provides vapor barrier protection, maximum strength, widest temperature range. Has very poor fl exibility.

C11 Thin Wall Polyolefi n. Semi-fl exible vapor barrier, no crush resistance -55 to +150°C

C12 Thin Wall Polyolefi n over SS Interlok. Flexible vapor barrier with good crush resistance…

C13 Furcation Tubing, PVC/Kevlar/PTFE High tensile strength, light crush resistance. Good for small diameter fiber models such as D20, RC19

ELECTRONICS Analog Output Amplifi ers – 0°C to 70°C Analog Amplifi ers with DPM – 0°C to 50°C Digital Amplifi ers – 0°C to 50°C

Tips

Cables

Amplifi ers

Temperature Limits

Questions and answers

What does 71_Temperature Limits cover?

SENSOR TIPS Standard sensor tips are constructed with glass fibers and stainless steel housings.

Which Philtec sensor models are mentioned?

This document mentions D20, RC19.