Reflectance Dependent Models – Analog

Philtec Model D100

Technical datasheet for the Philtec Model D100 reflectance-dependent analog fiberoptic displacement sensor. Ø 2.54 mm spot size, 10 mm total operating range, and DC–20 kHz bandwidth.

Philtec analog amplifier with the D100 probe Model D100 fiberoptic cable and sensor tip
Model D100 amplifier, 914 mm cable, and 3.18 mm probe tip

Technical datasheet for the Philtec Model D100 reflectance-dependent analog fiberoptic displacement sensor. Ø 2.54 mm spot size, 10 mm total operating range, and DC–20 kHz bandwidth.

Spot size2.54 mm0.100 in (targets > Ø 2.54 mm)
Total range10 mm9.6 mm (0.380 in) far side
Far side0.8 mV/µm19 mV/mil nominal
Linear range2.3 mm0.091 in far side nominal
BandwidthDC–20 kHzDC–200 kHz / 2 MHz or DC–100 Hz opt.

Overview

The Philtec Model D100 is a reflectance-dependent analog fiberoptic sensor for distance, displacement, and vibration of targets larger than Ø 2.54 mm (0.100 inch). Standard single-channel units include the amplifier and sensor tip with a 914 mm (3 foot) fiberoptic cable, require +12 VDC input power (+12 to +24 VDC operating range), and provide a 0 to +5 volt analog output with DC–20 kHz bandwidth.

Output voltage is proportional to both the distance between the sensor tip and target and the reflectivity of the target surface. The Far Side output function starts at the maximum output voltage referred to as the OPTICAL PEAK (set to 5.000 V at factory calibration), and D models are commonly used where target reflectivity stays constant, such as reciprocating or vibratory motion parallel to the axis of the sensor.

5.0 V 3.3 V 1.7 V 0.0 V OPTICAL PEAK (5.000 V) NEAR SIDE FAR SIDE Increasing Gap >>>
Figure 1. Near side, optical peak, and far side
  • Near side: steep slope rising to the peak as gap increases from contact.
  • Optical peak: maximum output voltage set to 5.000 V at factory calibration; gain control calibrates other target surfaces to 5 V.
  • Far side: primary calibrated region (0.8 mV/µm or 19 mV/mil nominal sensitivity; 9.6 mm / 0.380 in total range).

Specifications

Standard specifications — D100 Far Side (Analog Output 0–5 Volts)

Parameter Metric Imperial
Total range 9.6 mm (10 mm feature) 0.380 in
Linear range* 2.3 mm 0.091 in
Nominal standoff* 1.7 mm 0.068 in
Nominal sensitivity* 0.8 mV/µm 19 mV/mil
Resolution**, DC–200 kHz 8 µm 300 µin
Resolution**, DC–20 kHz 4 µm 150 µin
Resolution**, DC–100 Hz 0.5 µm 20 µin

Tip and cable dimensions

Feature Metric (mm) Imperial (inch)
Tip outer diameter (Ø C) 3.18 0.125
Fiberoptic diameter 2.54 0.100
Tip length (C) 76.2 3
Collar length (B) 12.7 0.5
Collar diameter (Ø B) 6.35 0.25
Cable length (A) 914 36
Cable diameter (Ø A) 5.7 0.225
Cable min. bend radius 25 1

Electronics

Light sourceLED, 850 nm
Input voltage+12 to +24 VDC
Input current125 mA max
BandwidthDC–20 kHz (3 dB down) standard; DC–200 kHz or higher (up to 2 MHz) and DC–100 Hz optional
Isothermal drift0.5%
Operating temperature0 to 70 °C
Weight0.7 kg (1.5 lb)

Fiberoptics

Light beam spread30°
Tip material300 Series SS
Tip epoxy outgas0.3% @ 200 °C; 2.4% @ 300 °C
Tip operating pressure15 bar
Tip operating temperature−55 to 200 °C continuous; to 300 °C intermittent (1–2 hours)
Cable operating temperature10 to 107 °C
Cable jacketPVC over Steel Monocoil

Nominal standoff is the gap (distance) that places the sensor at the middle of the linear operating range. *Standard specifications provide nominal values only; actual production values may vary by as much as ±15%.

**Resolution figures represent best-case performance where: the target is flat, smooth, and highly reflective; the sensor is perpendicular to the target; the sensor is gapped to its range of highest sensitivity; and fiberoptic cable lengths are standard with an unconnectorized cable.

Response curves

PHILTEC Model D100 — Typical Response (Far Side) 5.0 4.0 3.0 2.0 1.0 0.0 0 2 4 6 8 10 Gap, mm SENSITIVITY = −0.83 mV/µm
Figure 2. Model D100 typical response — Far Side (−0.83 mV/µm typical; 0.8 mV/µm nominal)
  • Linear range, Far Side, ±1%: 0.6 – 3.1 mm (2.3 mm nominal linear range).
  • Starts at the 5.000 V optical peak and decreases monotonically across the far side to ~10 mm.
PHILTEC Typical Model — Far Side (Front Surface Mirror) 5.0 4.0 3.0 2.0 1.0 0.0 0 0.2 0.4 0.6 0.8 1.0 Gap, mm SENSITIVITY = −6 mV/µm
Figure 3. Typical Far Side calibration example to front surface mirror
  • Linear range, Far Side, ±1%: 0.31 – 0.61 mm; Far Side Y-intercept: 6.709 V.
  • Noise ripple @ 3.5 VDC (DC–20 kHz): 6 mV pk-pk.
Typical Frequency Response — 2 Pole Butterworth Filter 0 -3 -6 -9 100 1000 10000 100000 Frequency, Hz (Gain dB)
Figure 4. Standard 20 kHz 2-pole Butterworth filter stays flat to about 6 kHz
AMPLIFIER DIMENSIONS inches (mm) 5.028 (127.7) 3.24 (82.4) 4 Slots: 0.157 × 0.375 (4 × 9.5 mm) 4.36 (110.8) 1.87 (47.6) 5.48 (139.2)
Figure 5. Standard enclosure for D models (5.48 × 3.24 × 1.87 in / 139.2 × 82.4 × 47.6 mm)

Distance from the analog output

A calibration chart is provided with each sensor giving the voltage output response to distance. There are three ways to derive accurate distance measurements: (a) within the bounds of the linear range, convert the change in voltage output using Distance = Δ milliVolts ÷ Sensitivity = µm; (b) over the non-linear range, create a lookup table using the XY calibration data points; or (c) use a polynomial curve fit to accurately map the sensor's output function.

500.00 µm · 19.685 mils

Questions

What target size and resolution does the Model D100 cover?

The Model D100 is designed for targets larger than Ø 2.54 mm (0.100 in) with a Ø 2.54 mm target spot size and 10 mm total operating range (9.6 mm / 0.380 in far-side specification). Best-case far-side resolution is 0.5 µm (20 µin) at DC–100 Hz, 4 µm (150 µin) at DC–20 kHz, and 8 µm (300 µin) at DC–200 kHz.

How is in-situ calibration performed on different target surfaces?

Changing target reflectance shifts the voltage output higher or lower. Factory calibrations have the Peak Voltage set to 5.000 V. Adjust the sensor's tip-to-target gap until the optical peak voltage is reached, then use the gain control to set the peak voltage to full scale (5.000 V), after which the factory gap calibration chart applies for that target.

What factory calibration information is provided with each sensor?

Calibration charts are provided for the Far Side region, typically listing the sensor model and serial number, date of calibration, linear sensing range, slope sensitivity, y-intercept of the linear range, and AC noise ripple, with XY calibration data points available upon request.

What bandwidth options are available for dynamic measurements?

DC–20 kHz bandwidth (2-pole Butterworth rolloff, 3 dB down at 20 kHz and flat out to ~6 kHz) is standard. DC–200 kHz or higher (up to 2 MHz) and DC–100 Hz (for best resolution) are optional.

Can the probe tip run hot or under pressure?

The 300-series stainless steel tip is rated from −55 to 200 °C continuous (and up to 300 °C intermittent for 1–2 hours) and up to 15 bar operating pressure, with tip epoxy outgas of 0.3% @ 200 °C and 2.4% @ 300 °C. The cable is rated 10 to 107 °C (PVC over steel monocoil), and the amplifier electronics are rated 0 to 70 °C.

Staging site at staging.philtec.com. Changes here do not affect the live site.