Reflectance Dependent Models – Analog

Philtec Model D20

Technical datasheet for the Philtec Model D20 reflectance-dependent analog fiberoptic displacement sensor. 510 µm spot size, 1.27 mm total range, and DC–20 kHz bandwidth.

Philtec analog amplifier with the D20 fiberoptic probe Fiberoptic cable and Model D20 sensor tip
Model D20 amplifier, 914 mm cable, and 0.81 mm probe tip

Technical datasheet for the Philtec Model D20 reflectance-dependent analog fiberoptic displacement sensor. 510 µm spot size, 1.27 mm total range, and DC–20 kHz bandwidth.

Spot size510 µm0.020 in
Total range1.27 mmFar side plus near side
Far side8 mV/µm215 mV/mil nominal
Near side90 mV/µm2,300 mV/mil nominal
BandwidthDC–20 kHz100 Hz to 200 kHz optional

Overview

The Philtec Model D20 is a reflectance-dependent analog fiberoptic sensor for distance, displacement, and vibration on small targets larger than 510 µm. A standard unit is the amplifier, the sensor tip, and a 914 mm (3 ft) cable. It runs on +12 to +24 VDC and provides a 0 to +5 V analog output.

Output voltage follows both the tip-to-target gap and the reflectivity of the target. D models are used where that reflectivity stays constant, such as motion along the sensor axis.

Typical D model output curve showing the near side, optical peak, and far side
Figure 1. Near side, optical peak, and far side
  • Near side: steep slope before the peak. High sensitivity, short range.
  • Optical peak: about 5 V. Reflectance only. This is the calibration reference.
  • Far side: gradual slope after the peak. Moderate sensitivity, longer range.

Specifications

Far side and near side

Parameter Far side Far side Near side Near side
Total range 1.15 mm 0.045 in 120 µm 5 mils
Linear range 0.25 mm 0.010 in 20 µm 0.8 mils
Nominal standoff 0.30 mm 0.012 in 28 µm 1.1 mils
Nominal sensitivity 8 mV/µm 215 mV/mil 90 mV/µm 2,300 mV/mil
Resolution, DC–200 kHz 0.25 µm 10 µin 20 nm 0.8 µin
Resolution, DC–20 kHz 0.1 µm 4 µin 10 nm 0.4 µin
Resolution, DC–100 Hz 0.04 µm 1 µin 2 nm 0.1 µin

Electronics

Light sourceLED, 850 nm
Input voltage+12 to +24 VDC
Input current125 mA max
BandwidthDC–20 kHz standard, 3 dB down
Amplifier temperature0 to 70 °C
Weight0.7 kg (1.5 lb)

Probe and cable

Tip material300 series stainless steel
Tip pressure15 bar
Tip temperature−55 to 200 °C continuous
Cable temperature10 to 107 °C
Cable jacketPVC over steel monocoil
Cable length914 mm (36 in)

Nominal standoff is the gap at the middle of the linear range. Published figures are nominal. Production units can vary.

Resolution figures assume a flat, smooth, reflective target, a perpendicular sensor, the gap of highest sensitivity, and a standard cable without connectors.

Response curves

Philtec Model D20 typical far side response, sensitivity minus 9 millivolts per micrometer
Figure 2. Far side, typical sensitivity −9 mV/µm
  • Linear range, ±1%: 0.14 mm to 0.36 mm.
  • The output peaks near 5 V at about 0.11 mm, then falls through the linear band.
Philtec Model D20 typical near side response, sensitivity 100 millivolts per micrometer
Figure 3. Near side, typical sensitivity 100 mV/µm
  • Linear range, ±1%: 16.8 µm to 34.8 µm.
  • Output rises from contact and levels near 5 V around 110 to 120 µm.
Typical frequency response of the standard 20 kilohertz 2-pole Butterworth filter
Figure 4. Standard bandwidth stays flat to about 6 kHz
Standard D model amplifier enclosure, top and side views, dimensions in inches and millimeters
Figure 5. Standard amplifier enclosure

Distance from the analog output

Inside a linear range, gap change equals the change in millivolts divided by sensitivity.

Questions

What target size and resolution does the Model D20 cover?

The spot size is 510 µm (0.020 in), for targets larger than that. Best near-side resolution is 2 nm at DC–100 Hz, and 10 nm at the standard DC–20 kHz bandwidth.

When is the near side used instead of the far side?

Use the near side for a short 20 µm linear range and about 90 mV/µm sensitivity. Use the far side for a 0.25 mm linear range, about 8 mV/µm, and more clearance from the target.

Can the probe tip run hot or under pressure?

The stainless tip is rated from −55 °C to 200 °C continuous and up to 15 bar. The amplifier electronics are rated 0 to 70 °C.