Reflectance Compensated Models – Analog
Philtec Model RC19
Technical datasheet for the Philtec Model RC19 reflectance-compensated analog fiberoptic displacement sensor. Ø 0.5 mm spot size for targets > Ø 0.5 mm, 0.76 mm total operating range, 9 mV/µm (225 mV/mil) nominal sensitivity, 0 to +5 V output, DC–20 kHz standard bandwidth, and resolution down to 0.05 µm.
Technical datasheet for the Philtec Model RC19 reflectance-compensated analog fiberoptic displacement sensor. Ø 0.5 mm spot size for targets > Ø 0.5 mm, 0.76 mm total operating range, 9 mV/µm (225 mV/mil) nominal sensitivity, 0 to +5 V output, DC–20 kHz standard bandwidth, and resolution down to 0.05 µm.
Overview & Reflectance Compensation
The Philtec Model RC19 is a reflectance-compensated analog fiberoptic displacement sensor designed for measuring distance, displacement, and vibration of small targets larger than Ø 0.5 mm with high resolution. RC Model sensors feature a pair of adjacent fiberoptic detectors in the sensor tip; light reflected off the target travels along two separate paths back to the electronics, where a ratiometric calculation yields a distance measurement independent of varying surface reflectance.
Analog sensors are fast-responding instruments suited to dynamic process control and vibration measurements. Standard single-channel units include the amplifier and sensor tip with a 914 mm (3 ft) glass fiberoptic cable, require +12 VDC input power (+12 to +24 VDC rated), and provide a 0 to +5 V analog output with DC–20 kHz bandwidth (optional DC–200 kHz or higher up to 350 kHz; optional DC–100 Hz for highest resolution).
- Ratiometric compensation: dual adjacent detectors cancel surface reflectance variations.
- Nominal standoff: 0.46 mm (0.018 in.) places the sensor at the center of the 0.3 mm (0.012 in.) linear range.
- Beam spread: 66° light beam spread from an 850 nm LED source.
Specifications
Standard specifications — Model RC19 (0–5 Volts Analog Output)
| Parameter | Metric | Imperial |
|---|---|---|
| Total range | 0.76 mm | 0.030 in. |
| Linear range* | 0.3 mm | 0.012 in. |
| Nominal standoff* | 0.46 mm | 0.018 in. |
| Nominal sensitivity* | 9 mV/µm | 225 mV/mil |
| Resolution** (DC – 200 kHz) | 0.8 µm | 32 µin |
| Resolution** (DC – 20 kHz) | 0.4 µm | 16 µin |
| Resolution** (DC – 100 Hz) | 0.05 µm | 2 µin |
| Weight | 0.7 kg | 1.5 lbs. |
Electronics
| Light source | LED, 850 nm |
|---|---|
| Input voltage | +12 to +24 VDC |
| Input current | 125 mA max |
| Bandwidth (3 dB down) | DC – 20 kHz (optional 200+ kHz up to 350 kHz; or DC – 100 Hz) |
| Isothermal drift | 0.5% |
| Operating temperature | 0 to 70 °C |
Fiberoptics
| Light beam spread | 66° |
|---|---|
| Tip material | 300 Series SS |
| Tip epoxy outgas | 0.3% @ 200 °C; 2.4% @ 300 °C |
| Tip operating pressure | 15 bar |
| Tip operating temperature | −55 to 200 °C continuous; to 300 °C intermittent (1–2 hours) |
| Cable jacket | PVC over Steel Monocoil (10 to 107 °C) |
NOTE: Nominal Standoff = the gap distance that places the sensor at the middle of the linear operating range. *Standard Specifications provide nominal values only; actual production values may vary by as much as ±15%.
**Resolution represents best-case performance where: the target is flat, smooth, and highly reflective; the sensor is perpendicular to the target; the sensor is gapped to its range of highest sensitivity; and fiberoptic cable lengths are standard with unconnectorized cable.
Tip, Cable & Amplifier Dimensions
| Feature | mm | inch |
|---|---|---|
| Tip outer diameter, Ø C | 0.81 | 0.032 |
| Fiberoptic Ø (Spot size: 0.5 mm) | 0.5 | 0.020 |
| Tip length, C | 38 | 1.5 |
| Collar length, B | 12.7 | 0.5 |
| Collar diameter, Ø B | 6.35 | 0.25 |
| Cable length, A | 914 | 36 |
| Cable diameter, Ø A | 5.2 | 0.205 |
| Cable min. bend radius | 12.7 | 0.5 |
Sensor Tip Alignment & Amplifier Enclosure
RC sensors have side-by-side adjacent fiberoptic bundles in the tip face. An alignment flat on the casing is ground parallel to the split between the adjacent fiberoptic bundles and located on the light-transmitting side.
| Amplifier body / flange L | 127.7 / 139.2 mm | 5.028 / 5.48 in. |
|---|---|---|
| Amplifier width / height | 82.4 / 47.6 mm | 3.24 / 1.87 in. |
| Mounting slots (4 places) | 54.6 × 110.8 mm (4 × 9.5 slots) | 2.15 × 4.36 in. (0.157 × 0.375 slots) |
| Flange thickness | 1.6 mm | 0.063 in. |
Typical Mirror Calibration & Frequency Response
- Example calibration values: Sensitivity = 9.7 mV/µm; Linear Range ±1% = 0.28–0.49 mm.
- Y-intercept: −1.820 Volts; Noise ripple @ 2.0 VDC (DC–20 kHz): 3 mV pk-pk.
- With 3 dB point at 20 kHz, output is flat out to approximately 6 kHz.
- Optional amplifiers set 3 dB down at 200 kHz or higher (up to 350 kHz) or at 100 Hz.
Converting Analog Output to Distance
Each sensor ships with a calibration chart listing model & serial number, calibration date, linear sensing range, slope sensitivity, y-intercept of the linear range, and AC noise ripple (XY calibration points available upon request). Three methods derive distance: (a) within the linear range, Distance (µm) = Δ milliVolts ÷ Sensitivity; (b) over the non-linear range, use a lookup table of XY calibration points; or (c) apply a polynomial curve fit.
200.00 µm (0.2000 mm · 7.87 mil)
Manufacturer & Contact
| Manufacturer | PHILTEC, Inc., Annapolis, MD USA |
|---|---|
| Phone / Fax / Email | 410-757-4404 · Fax 410-757-8138 · sensors@philtec.com |
Frequently asked questions
How does reflectance compensation work on the RC19?
The RC19 tip contains a pair of adjacent fiberoptic detectors. Light reflected from the target follows two separate paths back to the electronics, where a ratiometric calculation compensates for variations in target surface reflectance.
What is the purpose of the alignment flat on the RC19 tip/casing?
Because RC sensors use side-by-side adjacent fiberoptic bundles, an alignment flat is ground parallel to the split between the adjacent bundles on the light-transmitting side to aid sensor orientation.
What bandwidth options are available for the RC19 analog amplifier?
DC–20 kHz (2-pole Butterworth rolloff, flat to ~6 kHz) is standard, with optional high-frequency amplifiers at 200 kHz or higher (up to 350 kHz) and low-frequency amplifiers at 100 Hz for highest resolution (0.05 µm).